Plastic horizontal and vertical burning test machine
Scope of application:
The horizontal and vertical combustion tester mainly evaluates the flammability of V-0, V-1, V-2, HB, 5V, VMT grade materials. It is suitable for the research, production and quality inspection departments of electrical and electronic products and their components such as lighting equipment, low-voltage electrical appliances, household appliances, machine tool electrical appliances, motors, power tools, electronic instruments, electrical instruments, electrical connectors and accessories. In the industry of insulating materials, engineering plastics or other solid combustible materials.
Standards compliant:
Comply with the simulated safety test items stipulated by IEC60950, UL94, IEC707, IEC60695, ISO1210, GB/T5169, GB4943, GB/T2408-1996 and other standards.
Fundamental:
In the event of fire around the product, make sure that it does not cause the spread of combustion. Use a Bunsen burner of specified size and a specific gas source (methane or natural gas) to burn the horizontal or vertical test sample several times according to a certain flame height and a certain flame angle. Ignition, duration of scorching burning and burning length, etc. to evaluate its flammability and fire hazard.
The main parameters:
Lamps: Bunsen burner tube diameter is 9.5mm±0.5mm, and the length is about 100mm upward from the main air inlet or inlet.
Burning lamp moving method: pneumatic, stroke about 250mm
Lamp test inclination: 45°, 90° for quick positioning
Flame height: 20mm±2mm
Horizontal bracket adjustment method: manual
Sample height adjustment method: the electric motor drives the screw to make the sample holder move up and down
Fuel gas: 98% methane gas (reference gas), 37MJ/m3±1MJ/m3 natural gas can also be used
Combustion flow: less than 1l/min
Standard sample specifications: length 125mm, width 13mm, 3 < thickness < 13mm (or according to the test standard)
Timing count: burning time, stop time, continuous burning time, residual burning time, repeated burning times
Ignition method: electronic automatic ignition
Test area volume: ≥0.5m3, black background illumination ≤20Lx
Power supply: 220V, 0.5kVA, 50/60Hz.